Vista 5 M3 Digital Mixing System
3-28 Parameters
Document generated: 28.08.13
SW V4.9
Compressor Parameters:
CMP On/Off
Compressor on/off.
CMP THRS
Rotary The compressor threshold level can be adjusted in 1 dB steps from 0 dB
FS
to
–96 dB
FS
.
CMP REL
Rotary The compressor release time can be adjusted in 13 steps within a 10 ms to
10 s range (10 ms, 20 ms, 30 ms, 50 ms, 100 ms, 200 ms, 300 ms, 500 ms,
1 s, 2 s, 3 s, 5 s, and 10 s).
CMP hold on/off
Hold on = 150 ms, off = 0 ms.
CMP ATCK
Rotary The
compressor attack time can be adjusted in 9 steps within a 200 µs to 20 ms
range (0.2 ms, 0.3 ms, 0.5 ms, 1 ms, 2 ms, 3 ms, 5 ms, 10 ms, and 20 ms).
CMP RTIO
Rotary
The compressor ratio
can be adjusted from 1:1 (no com pression) to 20:1
0
–5
–10
–15
–20
–25
–30
–35
–40
–45
–50
–55
–60
–65
–70
–75
–80
–85
–90
–10
–20
–30
–40
–50
–60
–70
–80
–90
0
Input level
[dBFS]
Output level
[dBFS]
1
2
6
5
4
3
(heavy compression) in the following steps: 1:1, 5:4, 4:3, 3:2, 5:3, 2:1, 3:1,
5:1, 7:1, 10:1, and 20:1.
Curve
Compressor
Threshold [dB]
Ratio
1
OFF
any
any
1
ON
0
1:1
2
ON
–20
20:1
3
ON
–40
20:1
4
ON
–40
20:1
5
ON
–40
5:1
6
ON
–40
2:1
Expander Parameters:
EXP On/Off
Expander on/off.
EXP THRS
Rotary The expander threshold level can be adjusted in 1 dB steps from 0 dB
FS
to
–96 dB
FS
.
EXP REL
Rotary The expander release time can be adjusted in 13 steps within a 10 ms through
10 s range (10 ms, 20 ms, 30 ms, 50 ms, 100 ms, 200 ms, 300 ms, 500 ms,
1 s, 2 s, 3 s, 5 s, and 10 s).
EXP hold on/off
Hold on = 150 ms, off = 0 ms.
EXP ATCK
Rotary The expander attack time can be adjusted in 9 steps within a 200 µs to 1 ms
range (0.2 ms, 0.3 ms, 0.4 ms, 0.5 ms, 0.6 ms, 0.7 ms, 0.8 ms, 0.9 ms, and
1 ms).
EXP RTIO
Rotary
The expander ratio
can be adjusted from 1:1 (no expansion) to 1:20 (heavy
expansion) in the following steps: 1:1, 1:1.3, 1:1.4, 1:1.5, 1:1.7, 1:2, 1:3, 1:5,
1:7, 1:10, and 1:20.
0
–5
–10
–15
–20
–25
–30
–35
–40
–45
–50
–55
–60
–65
–70
–75
–80
–85
–90
–10
–20
–30
–40
–50
–60
–70
–80
–90
0
Input level
[dBFS]
Output level
[dBFS]
2 3
4
5
6 7
1
Curve
Expander
Threshold [dB]
Ratio
1
OFF
any
any
1
ON
–96
any
1
ON
–30
1:1
2
ON
–60
1:2
3
ON
–60
1:5
4
ON
–60
1:20
5
ON
–30
1:2
6
ON
–30
1:5
7
ON
–30
1:20
Summary of Contents for Vista 5 M3
Page 18: ...Vista 5 M3 Digital Mixing System 1 2 Introduction Document generated 28 08 13 SW V4 9 ...
Page 40: ...Vista 5 M3 Digital Mixing System 1 24 Introduction Document generated 28 08 13 SW V4 9 ...
Page 90: ...Vista 5 M3 Digital Mixing System 3 2 Parameters Document generated 28 08 13 SW V4 9 ...
Page 144: ...Vista 5 M3 Digital Mixing System 3 56 Parameters Document generated 28 08 13 SW V4 9 ...
Page 300: ...Vista 5 M3 Digital Mixing System 5 4 AutoTouchPlus Document generated 28 08 13 SW V4 9 ...
Page 348: ...Vista 5 M3 Digital Mixing System 5 52 AutoTouchPlus Document generated 28 08 13 SW V4 9 ...
Page 506: ...Vista 5 M3 Digital Mixing System 7 2 DAW Control Document generated 28 08 13 SW V4 9 ...
Page 516: ...Vista 5 M3 Digital Mixing System 7 12 DAW Control Document generated 28 08 13 SW V4 9 ...
Page 518: ...Vista 5 M3 Digital Mixing System 8 2 RELINK Document generated 28 08 13 SW V4 9 ...