Vista 5 M3 Digital Mixing System
AutoTouchPlus 5-85
Document generated: 28.08.13
SW V4.9
As with any control, changes to General Patch connections may be Audi-
tioned.
Record a General Patch Change
To automate a connection in the General Patch, use the following procedure:
1.
Select the desired global Control Mode.
Write
will overwrite previous
changes, both location and connection type.
2.
Select
TOUCH – Record
.
3.
Select the desired
Write To:
and
Extend Back To:
functions.
4.
Open the General Patch if it is not already open.
5.
Select the connection point to be automated (single click at the desired
location).
6.
Make/break the desired connection as follows:
• To make a simple mono-to-mono connection, press the
MAKE CON-
NECT
function key above the trackball. (Double-clicking the connec-
tion location will bring up the connection menu where a mono-to-
mono connection may be made.)
• To make a complex connection (mono-to-stereo, stereo-to-stereo,
stereo-to-mono), double-clicking the connection location will bring
up the connection menu where the desired connection may be made.
• To break any connection, press the
BREAK CONNECT
function key
above the trackball. (Double-clicking the connection location will
bring up the connection menu where a connection may be broken.)
7.
Upon the selection of the desired connection type, AutoTouchPlus will
punch-in. Following the rules for Press and Hold, the new connection
state will persist until the
Write To:
conditions are met or a Global Punch-
out occurs.
8.
When timecode is stopped, a new Mix Pass will be generated.
Note
Like any other object within AutoTouchPlus, all General Patch connection
points are Static objects until a change state is recorded in the system. There-
fore, General Patch connections may be updated in the same manner as any
other Static control.
Summary of Contents for Vista 5 M3
Page 18: ...Vista 5 M3 Digital Mixing System 1 2 Introduction Document generated 28 08 13 SW V4 9 ...
Page 40: ...Vista 5 M3 Digital Mixing System 1 24 Introduction Document generated 28 08 13 SW V4 9 ...
Page 90: ...Vista 5 M3 Digital Mixing System 3 2 Parameters Document generated 28 08 13 SW V4 9 ...
Page 144: ...Vista 5 M3 Digital Mixing System 3 56 Parameters Document generated 28 08 13 SW V4 9 ...
Page 300: ...Vista 5 M3 Digital Mixing System 5 4 AutoTouchPlus Document generated 28 08 13 SW V4 9 ...
Page 348: ...Vista 5 M3 Digital Mixing System 5 52 AutoTouchPlus Document generated 28 08 13 SW V4 9 ...
Page 506: ...Vista 5 M3 Digital Mixing System 7 2 DAW Control Document generated 28 08 13 SW V4 9 ...
Page 516: ...Vista 5 M3 Digital Mixing System 7 12 DAW Control Document generated 28 08 13 SW V4 9 ...
Page 518: ...Vista 5 M3 Digital Mixing System 8 2 RELINK Document generated 28 08 13 SW V4 9 ...