9.4 Error Diagnosis Due To Operating Status
9-45
9
Abnormal noise
Mechanical mounting is incorrect.
Check if Servomotor
mounting screws loose.
Tighten mounting screws.
Check if coupling not cen-
tered.
Center coupling.
Check if coupling unbal-
anced.
Balance coupling.
Bearing is defective.
Check noise and vibration
near bearing.
Remove the cause of problem
and repair.
Machine causing vibrations
Check for presence of for-
eign object, damage or
deformation of movable
parts of machine.
Remove the cause of problem
and repair.
Table 9.3 Troubleshooting Table with No Alarm Display (cont’d)
Symptom
Cause
Inspection
Remedy