9.3 Troubleshooting with Alarm Displays
9-25
9
A.96
A.96: Communications Warning
Display and Outputs
Note
OFF: Output transistor is OFF (alarm state). ON: Output transistor is ON.
Status and Remedy for Alarm
A.98
A.98: Main Power OFF
Display and Outputs
Note
OFF: Output transistor is OFF (alarm state). ON: Output transistor is ON.
Status and Remedy for Alarm
Alarm Outputs
Alarm Code Outputs
ALM Output
ALO1
ALO2
ALO3
OFF
ON
ON
ON
Cause
Remedy
A
Cable and connector contact is faulty.
Correct the connector wiring.
B
Malfunction due to noise.
Take noise prevention measures.
Alarm Outputs
Alarm Code Outputs
ALM Output
ALO1
ALO2
ALO3
OFF
OFF
OFF
ON
Cause
Remedy
A
Power supply cable and the connector con-
tact is faulty.
Correct the connector wiring
.
B
Power Supply Unit is defective.
Check the Power Supply Unit.
A, B
During DeviceNet
communications
A, B
When main power supply
OFF