9 Troubleshooting
9-42
9
CPF00
CPF00: Parameter Unit Transmission Error 1
This alarm is not stored in the alarm record function memory.
Display and Outputs
Status and Remedy for Alarm
Alarm Outputs
Alarm Code Outputs
ALM Output
ALO1
ALO2
ALO3
Not specified
Cause
Remedy
A
Cable defective or poor contact between
Parameter Unit and Servo Driver
• Check connector connections.
• Replace cable.
B
Malfunction due to external noise
Separate Parameter Unit and cable from
noise source.
C
Parameter Unit is defective.
Replace Parameter Unit.
D
The Servo Driver is defective.
Replace the Servo Driver.
A,
B,
C,
D
A,
B,
C,
D
At
power
ON.
Parameter
Unit
connected
before
Servo
Driver
power
turned
ON.
Parameter
Unit
connected
to
Servo
Driver
while
power
turned
ON.
Summary of Contents for OMNUC W R88A-NCW152-DRT
Page 1: ...Cat No I538 E3 1 DeviceNet Option Unit OMNUC W Series Model R88A NCW152 DRT...
Page 53: ...4 Connectors 4 5 3 DeviceNet Network Configuration Restrictions 4 22 4...
Page 97: ...5 Parameter Settings 5 3 8 Notch Signal Output Positioning 5 44 5...
Page 211: ...8 Servo Driver Settings 8 5 3 Absolute Encoder Multi turn Limit Setting 8 24 8...
Page 257: ...9 Troubleshooting 9 46 9...