6 DeviceNet Communications
6.5.4 Set/Read Commands for Remote I/O Communications
6-40
6
Monitor Mode Read Command (Command Code: 1101, D Hex)
The Monitor Mode Read Command reads the I/O status and internal data for the various sig-
nals displayed on the Servo Driver.
To use the Monitor Mode Read Command, make the following settings and then change the
Command Start Command from 0 to 1.
• Command code
• Monitor number
(The monitor number indicates the three characters following Un in
displayed on
the Servo Driver. For Un00C and Un00D, only the lowest 16 bits are read.)
Table 6.21 Commands for Monitor Mode Read Command
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
1
0
ALRST
STOP
0
0
SVON
C_STRT
1
0
D Hex
2
Monitor No.
3
4
0
5
6
7
Table 6.22 Responses for Monitor Mode Read Command
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
1
READY
PWRON
STOP_R
ALRM
WARN
SVON_R C_STRT_R
1
0
D Hex
2
Monitor No.
3
4
Monitor data
5
6
0
7