9 Troubleshooting
9-36
9
A.E2
A.E2: WDC Error of DeviceNet Unit
Display and Outputs
Note
OFF: Output transistor is OFF (alarm state). ON: Output transistor is ON.
Status and Remedy for Alarm
A.E6
A.E6: DeviceNet Duplicate MAC ID Error
Display and Outputs
Note
OFF: Output transistor is OFF (alarm state). ON: Output transistor is ON.
Status and Remedy for Alarm
Alarm Outputs
Alarm Code Outputs
ALM Output
ALO1
ALO2
ALO3
OFF
ON
ON
OFF
Cause
Remedy
A
The DeviceNet Unit is defective.
Replace the DeviceNet Unit.
Alarm Outputs
Alarm Code Outputs
ALM Output
ALO1
ALO2
ALO3
OFF
ON
ON
OFF
Cause
Remedy
A
Duplicate node address
Check node addresses of all Units on the
DeviceNet network.
A
At power ON
A
Duplicate MAC ID