Unit Reset Command (Command Code: 1110, E Hex)
When the Unit Reset Command is executed, the parameters for the W-series Servo Driver
and the DeviceNet Unit are stored in flash ROM and then the DeviceNet Unit is restarted.
To use the Unit Reset Command, make the command code settings and then change the
Command Start Command from 0 to 1.
When the DeviceNet Unit is resetting the Unit, the Unit Ready Flag is set to 0. When the
reset has been completed, the flag is set to 1.
Table 6.23 Commands for Unit Reset Command
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
1
0
ALRST
STOP
0
0
SVON
C_STRT
1
0
E Hex
2
0
3
4
0
5
6
7
Table 6.24 Responses for Unit Reset Command
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
1
READY
PWRON
STOP_R
ALRM
WARN
SVON_R C_STRT_R
1
0
E Hex
2
0
3
4
0
5
6
7