9.3 Troubleshooting with Alarm Displays
9-11
9
A.32
A.32: Regeneration Overload
Display and Outputs
Note
OFF: Output transistor is OFF (alarm state). ON: Output transistor is ON.
Status and Remedy for Alarm
Alarm Outputs
Alarm Code Outputs
ALM Output
ALO1
ALO2
ALO3
ON
ON
OFF
OFF
Cause
Remedy
A
Regenerative power exceeds the allowable
value.
Use an external regenerative resistor that
matches the regenerative power capacity.
B
Alarm occurs although an external regener-
ative resistor is used and the temperature
rise of the regenerative resistor is small.
Reset the incorrect Pn600 user parameter
setting.
A, B
During Servomotor
operation