6 DeviceNet Communications
6.5.3 Move Commands for Remote I/O Communications
6-30
6
Movement Direction: DIR (Byte 3, Bit 1)
The DR bit specifies the movement direction. Set this bit to 0 for positive direction and
to 1 for negative direction.
This specification is used for the following commands.
• JOG Command
• Step Command
• Station Command
The movement direction specification is disabled during normal positioning.
Responses
The responses for move commands are shown below.
Status
The status for move commands is described below.
Progressing Flag: PRGS (Byte 2, Bit 0)
The PRGS bit
is set to 1 during the execution of a command. For move commands, this
flag will be set to 1 while outputting to the W-series Servo Driver.
When command execution has been completed or when a Cancel Command or other
stop command has been received, the Progressing Flag is set to 0.
Holding Flag: HOLD_R (Byte 2, Bit 1)
The HOLD_R bit is set to 1 when a Hold Command is received from the host device and
for the duration of the hold.
The host device can confirm that the DeviceNet Unit correctly received the Hold
Command by checking that the Holding Flag is set to 1.
Table 6.7 Responses for Move Commands
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
0
READY
PWRON
STOP_R
ALRM
WARN
SVON_R C_STRT_R
1
Response type
Command code
2
HOME_
R
PTBL_R
STN_R
STEP_R
JOG_R
0
HOLD_R
PRGS
3
POT
NOT
INPOS
NEAR
HOME_P
0
DIR_R
INC_R
4
Response data
5
6
7
General
status
Status
Summary of Contents for OMNUC W R88A-NCW152-DRT
Page 1: ...Cat No I538 E3 1 DeviceNet Option Unit OMNUC W Series Model R88A NCW152 DRT...
Page 53: ...4 Connectors 4 5 3 DeviceNet Network Configuration Restrictions 4 22 4...
Page 97: ...5 Parameter Settings 5 3 8 Notch Signal Output Positioning 5 44 5...
Page 211: ...8 Servo Driver Settings 8 5 3 Absolute Encoder Multi turn Limit Setting 8 24 8...
Page 257: ...9 Troubleshooting 9 46 9...