7.3 Programming Explicit Messages
7-9
7
MOV (021)
#4900
D00004
BSET (071)
#0000
D00100
D00199
MOV (021)
#0009
D00200
MOV (021)
#000C
D00201
MOV (021)
#0000
D00202
MOV (021)
#0010
D00203
MOV (021)
#0000
D00204
MOV (021)
#0064
D00205
Continued
on next page.
Sets number of
response bytes
to 12.
From
previous page.
Sets service data.
Clears response
storage area.
Sets number of
command bytes
to 9.
Sets destination
network address
to 0.
Sets destination node address
to 0, and sets destination
unit address to 10 Hex.
Sets response returned to
0, communications port number
to 0, and number of retries to 0.
Sets response monitoring
time to 100 ms.