Page 1: ...www go4b com RG1 ROTARY LEVEL INDICATOR INSTALLATION INSTRUCTIONS OPERATION MANUAL Part No s RG1V56A RG1V4A ...

Page 2: ......

Page 3: ...UCT OVERVIEW Page 6 SPECIFICATIONS Page 6 DIMENSIONS Page 6 INSTALLATION Page 7 STANDARD WIRING DIAGRAM Page 8 TESTING AND COMMISSIONING Page 10 TROUBLESHOOTING GUIDE Page 10 PARTS AND ACCESSORIES Page 11 PRODUCT WARRANTY Page 15 TABLE OF CONTENTS ...

Page 4: ...responsibility of the user unless you have asked 4B to perform these tasks B All installation and wiring must be in accordance with Local and National Electrical Codes and other standards applicable to your industry The installation of the wiring should be undertaken by an experienced and qualified professional electrician Failure to correctly wire any product and or machinery can result in the pr...

Page 5: ...uction work at the facility hours of operation animal or insect infestation and the real world experience of knowing how your employees perform their jobs The personnel or person you select to install operate maintain inspect or perform any work whatsoever should be trained and qualified to perform these important functions Complete and accurate records of the maintenance and inspection process sh...

Page 6: ...ny inlet or outlet to close down or start up When the level of the material reaches normal levels again the motor returns to its initial position and restarts SPECIFICATIONS Power Supply RG1V56A 110 240 VAC RG1V4A 24 VDC Operating Temp 20 C up to 70 C Output Change over relay 10 A at 250 VAC Mounting ø 2 1 2 BSPT Gas Paddle Standard NYLON propeller available on request in stainless steel or other ...

Page 7: ...hand side Figure 1 The level gauge is mounted on silos or vessels on the side or top It is important to choose the position so that the device is outside of the product flow likewise taking care that the material can move freely all around the gauge Protective deflectors Figure 2 are advisable when there is considerable weight load on the shaft or when material flow is unevem and lumps of product ...

Page 8: ... the cable entry It is realised via M5 screw and eyelet cable crimp The external earthing has to be carried out by the installer The equipment has to be protected against impact and electrostatic inside the silo The user has to protect the equipment circuits with fuses against short circuit The maximum surface temperature is determined taking into account a safety margin but without considering a ...

Page 9: ...PAGE 9 Figure 4 110 240 VAC Wiring detail Figure 5 24 VDC Wiring detail ...

Page 10: ...olutely forbidden for children unauthorized and or inexperienced persons to touch or use the level gauge Make sure that the electricity system complies with the laws in force Make sure that the earthing is efficiently connected when the instrument is installed Make sure that the power socket is suitable that it complies with the laws in force and that it has a built in automatic protection circuit...

Page 11: ...in NYLON ø120 x 100 mm RG1SP3 3 Vanes NYLON screw ø120 x 65 mm RG1SP1 SS Single vane screw in Stainless steel ø120 x 100 mm RG1SP4 SS 4 Vanes Stainless steel screw ø100 x 60 mm RG1SP4 SS L 4 Vanes Stainless steel screw mounting with flange ø138 x 60 mm RG1SPV SS 1 Vanes Stainless steel screw ...

Page 12: ...ess steel extension without rod guard 1000 mm 1 m long RG1EXT 1500 SS Stainless steel extension without rod guard 1500 mm 1 5 m long RG1EXT 0500 SS G Extension with rod guard in stainless steel 500 mm 0 5 m long RG1EXT 1000 SS G Extension with rod guard in stainless steel 1000 mm 1 m long RG1EXT 1500 SS G Extension with rod guard in stainless steel 1500 mm 1 5 m long ...

Page 13: ...aluminium flange External diameter 203 mm holes centers ø178 mm 6 equidistant ø7 5 holes RG1 TUBE 2 5 Iron sleeve 2 1 2 BSPP Gas RG1 TUBE 2 5 SS Stainless steel sleeve 2 1 2 BSPP Gas SPARES RG1MOTOR SPARE Geared motor that can be installed on any bladed level indicator Available power supplies V 110 220 a c 50 60 Hz V 24 d c Power consumption 4 Watt PAGE 13 ...

Page 14: ...teel ø120 x 100 mm SUGGESTED MATERIAL DENSITY kg dm3 between 0 6 and 0 9 MIN INSTALLATION HOLE DIMENSION mm 65 For medium weight materials RG1SP4 SS 4 Vanes Stainless steel screw ø100 x 60 mm SUGGESTED MATERIAL DENSITY kg dm3 between 0 3 and 0 5 MIN INSTALLATION HOLE DIMENSION mm 105 For lightweight and medium weight materials RG1SP4 SS L 4 Vanes Stainless steel screw mounting with flange ø138 x 6...

Page 15: ...ISUSE ABUSE OR MISAPPLICATIONS AS AUTHORIZED BY LAW 4B SPECIFICALLY DISCLAIMS ALL WARRANTIES THAT THE PRODUCT IS FIT OR MERCHANTABLE FOR A PARTICULAR PURPOSE 3 NO WARRANTY BY SAMPLE OR EXAMPLE ALTHOUGH 4B HAS USED REASONABLE EFFORTS TO ACCURATELY ILLUSTRATE AND DESCRIBE THE PRODUCTS IN ITS CATALOGS LITERATURE AND WEBSITES SUCH ILLUSTRATIONS AND DESCRIPTIONS ARE FOR THE SOLE PURPOSE OF PRODUCT IDEN...

Page 16: ...erlord Place Acacia Ridge Queensland 4110 Australia Tel 61 0 7 3711 2565 Fax 61 0 7 3711 2574 4B COMPONENTS LTD 625 Erie Avenue Morton IL 61550 USA Tel 309 698 5611 Fax 309 698 5615 4B BRAIME COMPONENTS LTD Hunslet Road Leeds LS10 1JZ United Kingdom Tel 44 0 113 246 1800 Fax 44 0 113 243 5021 4B DEUTSCHLAND 9 Route de Corbie Lamotte Warfusée F 80800 France Tel 49 0 700 2242 4091 Fax 49 0 700 2242 ...