6.5 Remote I/O Communications
6-39
6
Alarm Read Command (Command Code: 1100, C Hex)
The Alarm Read Command reads the last four alarms that have occurred on the W-series
Servo Driver and the DeviceNet Unit. Refer to
10.3 Alarm/Warning Codes and Error Codes
for Message Communications
to check alarms.
To use the Alarm Read Command, make the command code settings and then change the
Command Start Command from 0 to 1.
Table 6.19 Commands for Alarm Read Command
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
1
0
ALRST
STOP
0
0
SVON
C_STRT
1
0
C Hex
2
0
3
4
0
5
6
7
Table 6.20 Responses for Alarm Read Command
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
1
READY
PWRON
STOP_R
ALRM
WARN
SVON_R C_STRT_R
1
0
C Hex
2
0
3
4
Last alarm code
5
Second last alarm code
6
Third last alarm code
7
Fourth last alarm code