10.2 DeviceNet Attributes
10-25
10
10.2.9 Trace Setting Object (0x67)
Class and instances of the Trace Setting Object (0x67) are shown below.
Class
• Attributes: None supported
• Services: None supported
Instances
Attributes (Instance #1: Explicit Message)
No.
Access
Name
Data Type
Description
Setting
Range
Default
Setting
10
Get/Set
Data Trace 1
UINT
Specifies the data trace 1 target.
0 to 4
0
11
Get/Set
Data Trace 2
UINT
Specifies the data trace 2 target.
0 to 4
1
12
Get/Set
I/O Trace 1
UINT
Specifies the I/O trace 1 target.
80 to 8D Hex
83 Hex
13
Get/Set
I/O Trace 2
UINT
Specifies the I/O trace 2 target.
80 to 8D Hex
81 Hex
14
Get/Set
Sampling Cycle
DINT
Specifies the sampling cycle.
Unit:
µ
s
250 to
8191750
250
15
Get/Set
Trigger Target
UINT
Specifies the trigger condition.
0 to 4
0
16
Get/Set
Trigger Level
UINT
Specifies the trigger level.
0000 to FFFF
Hex
0
17
Get/Set
Edge Type
UINT
Specifies the edge type.
0 to 2
0
18
Get/Set
Pre-trigger
UINT
Specifies the amount of pre-trigger data.
0 to 999
0
19
Get/Set
Start Trace
UINT
Specifies the trace execution status.
0: No-operation (initial status)
1: Trace Start Command
2: Trace Stop Command
0 to 2
0
20
Get
Trace State
UINT
Stores the trace execution status.
0000 Hex: Initial status
0001 Hex: Tracing data.
0002 Hex: Trace completed.
(Read enabled.)
0010 Hex: Trace interrupted.
0011 Hex: Setting error
−
0
Summary of Contents for OMNUC W R88A-NCW152-DRT
Page 1: ...Cat No I538 E3 1 DeviceNet Option Unit OMNUC W Series Model R88A NCW152 DRT...
Page 53: ...4 Connectors 4 5 3 DeviceNet Network Configuration Restrictions 4 22 4...
Page 97: ...5 Parameter Settings 5 3 8 Notch Signal Output Positioning 5 44 5...
Page 211: ...8 Servo Driver Settings 8 5 3 Absolute Encoder Multi turn Limit Setting 8 24 8...
Page 257: ...9 Troubleshooting 9 46 9...