10 Appendix
10.2.6 DeviceNet Unit Parameter Object (0x64)
10-12
10
94
Get/Set
Interrupt Feeding
Positioning Speed
DINT
Sets the positioning speed for interrupt
feeding.
Unit:
×
1000 steps/min
1 to 240,000
24,000
95
Get/Set
Interrupt Feeding
Distance
DINT
Sets the amount of interrupt feeding.
Unit: Steps
-99,999,999
to 99,999,999
0
96
Get/Set
Interrupt Feeding
Function Selection
UINT
Sets the polarity of interrupt input signals.
0, 1
0
100
Get/Set
Station
UINT
Sets the number of stations.
1 to 32,767
1
111
Get/Set
Speed Switch
Point
UINT
Sets the number of speed switching points.
0 to 16
0
112
Get/Set
Multi-speed Posi-
tioning Initial Speed
DINT
Sets the initial speed for multi-speed.
Unit:
×
1000 steps/min
1 to 240,000
24,000
113
Get/Set
Position 1 for
Multi-speed
DINT
Sets speed-switching position 1 for multi-
speed.
Unit: Steps
0 to
99,999,999
0
114
Get/Set
Position 2 for
Multi-speed
DINT
Sets speed–switching position 2 for multi-
speed.
Unit: Steps
0 to
99,999,999
0
115
Get/Set
Position 3 for
Multi-speed
DINT
Sets speed-switching position 3 for multi-
speed.
Unit: Steps
0 to
99,999,999
0
116
Get/Set
Position 4 for
Multi-speed
DINT
Sets speed-switching position 4 for multi-
speed.
Unit: Steps
0 to
99,999,999
0
117
Get/Set
Position 5 for
Multi-speed
DINT
Sets speed-switching position 5 for multi-
speed.
Unit: Steps
0 to
99,999,999
0
118
Get/Set
Position 6 for
Multi-speed
DINT
Sets speed-switching position 6 for multi-
speed.
Unit: Steps
0 to
99,999,999
0
119
Get/Set
Position 7 for
Multi-speed
DINT
Sets speed-switching position 7 for multi-
speed.
Unit: Steps
0 to
99,999,999
0
120
Get/Set
Position 8 for
Multi-speed
DINT
Sets speed-switching position 8 for multi-
speed.
Unit: Steps
0 to
99,999,999
0
121
Get/Set
Position 9 for
Multi-speed
DINT
Sets speed-switching position 9 for multi-
speed.
Unit: Steps
0 to
99,999,999
0
122
Get/Set
Position 10 for
Multi-speed
DINT
Sets speed-switching position 10 for multi-
speed.
Unit: Steps
0 to
99,999,999
0
123
Get/Set
Position 11 for
Multi-speed
DINT
Sets speed–switching position 11 for multi–
speed.
Unit: Steps
0 to
99,999,999
0
124
Get/Set
Position 12 for
Multi-speed
DINT
Sets speed-switching position 12 for multi-
speed.
Unit: Steps
0 to
99,999,999
0
125
Get/Set
Position 13 for
Multi-speed
DINT
Sets speed-switching position 13 for multi-
speed.
Unit: Steps
0 to
99,999,999
0
(cont’d)
No
Access
Name
Data Type
Description
Setting
Range
Default
Setting
Summary of Contents for OMNUC W R88A-NCW152-DRT
Page 1: ...Cat No I538 E3 1 DeviceNet Option Unit OMNUC W Series Model R88A NCW152 DRT...
Page 53: ...4 Connectors 4 5 3 DeviceNet Network Configuration Restrictions 4 22 4...
Page 97: ...5 Parameter Settings 5 3 8 Notch Signal Output Positioning 5 44 5...
Page 211: ...8 Servo Driver Settings 8 5 3 Absolute Encoder Multi turn Limit Setting 8 24 8...