4 Connectors
4.4.3 I/O Signal Interface Circuits
4-12
4
CN4 Connector Specifications
4.4.3 I/O Signal Interface Circuits
The following diagram shows an example of connections between a host controller and the
I/O signals for a DeviceNet Unit.
Sequence Input Circuit
The sequence input circuit connects through a relay or open-collector transistor circuit.
Select a low-current relay, otherwise a faulty contact will result
.
Sequence Output Circuit
Notch output signals are used for photocoupler output circuits. Connect the notch output
signals to relays or line receiver circuits.
Note
The maximum allowable voltage and current capacity for photocoupler output circuits are as follows
:
• Voltage: 30 V DC max.
• Current: 50 mA DC max.
Part
Signal
Manufacturer
Connector
10120-3000VE (20P)
Sumitomo 3M Ltd.
Connector shell
10320-52A0-008
−
+24VIN
3.3 k
Ω
STOP
24 V DC
50 mA min.
DeviceNet Unit
+24VIN 3.3 k
Ω
STOP
24 V DC
50 mA min.
DeviceNet Unit
Relay
Open Collector
0 V
5 to 24 V DC
Relay
DeviceNet
Unit end
P
0 V
Relay
Line Receiver
DeviceNet
Unit end
5 to 12 V DC