425
Serial Communications
Section 8-3
Procedure
Host Link Commands
The following table lists the host link commands. Refer to the SYSMAC
CS/CJ-series Communications Commands Reference Manual (W342) for
more details.
Set the PLC Setup from the CX-
Programmer.
(Set the communications mode to
Host Link and set the parameters.)
Power OFF
Connect the CPU Unit and external device
via RS-232C. (Mount the RS-232C Option
Board in option slot 1 or 2.)
Set the DIP switch on the front of
the CPU Unit.
Turn pin 4 OFF when suing serial port 1.
Turn pin 5 OFF when suing serial port 2.
Power ON
Host computer to PLC
PLC to Host computer
Send Host Link
commands from
the host computer.
Send FINS
commands from
the host computer.
Execute SEND/RECV/CMND
instructions in the PLC’s program.
Return a response from the host
computer. (A program is required in
the host computer.)
Type
Header
code
Name
Function
I/O mem-
ory read
commands
RR
CIO AREA READ
Reads the contents of the specified number of CIO Area words starting from
the specified word.
RL
LINK AREA READ
Reads the contents of the specified number of Link Area words starting from
the specified word.
RH
HR AREA READ
Reads the contents of the specified number of Holding Area words starting
from the specified word.
RC
PV READ
Reads the contents of the specified number of timer/counter PVs (present
values) starting from the specified timer/counter.
RG
T/C STATUS READ Reads the status of the Completion Flags of the specified number of tim-
ers/counters starting from the specified timer/counter.
RD
DM AREA READ
Reads the contents of the specified number of DM Area words starting from
the specified word.
RJ
AR AREA READ
Reads the contents of the specified number of Auxiliary Area words starting
from the specified word.
Summary of Contents for CP1L-EL20DR-D
Page 3: ...CP1L EL20D CP1L EM30D CP1L EM40D CP1L EL EM CPU Unit Operation Manual Produced July 2017...
Page 4: ...iv...
Page 10: ...x...
Page 22: ...xxii...
Page 34: ...xxxiv Software Licenses and Copyrights 7...
Page 192: ...158 Trial Operation and Debugging Section 5 3...
Page 250: ...216 Automatic Clock Adjustment and Specifying Servers by Host Name Section 6 7...
Page 666: ...632 Trouble Shooting Section 11 7...
Page 696: ...662 Standard Models Appendix A...
Page 805: ...771 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 806: ...772 Connections to Serial Communications Option Boards Appendix F...
Page 836: ...802 PLC Setup Appendix G...
Page 838: ...804 TCP Status Transitions Appendix H...
Page 840: ...806 Ethernet Network Parameters Appendix I...
Page 842: ...808 Buffer Configuration CP1L EL EM Appendix J...
Page 844: ...810 Ethernet Specifications Appendix K...
Page 851: ...Index 817 work words 118 write protection 447...
Page 852: ...818 Index...
Page 854: ...820 Revision History...
Page 855: ......