175
FINS Communications
Section 6-5
CX-Programmer Setup
FINS/UDP
Move the cursor to the
Settings
and double click. Select the Built-in Ethernet
Tab. Click the
FINS/UDP Setting
button to display the FINS/UDP setup dialog.
Note
Make settings using the PLC settings function in the CX-Programmer (to be
included in version 9.4 and higher).
Item
Contents
Default
FINS/UDP Port
Specify the local UDP port number to be used for the FINS communica-
tions service. The UDP port number is the number used for UDP identi-
fication of the application layer (i.e., the FINS communications service in
this case).
• Default (9,600)
• User defined (Setting range: 1 to 65,535)
Note:
Make the settings so that UDP port number does not overlap with
port number 123 for SNTP and port number 53 for DNS.
0
(9,600)
Conversion
Select any of the following as the method for finding and converting IP
addresses from FINS node addresses. (Enabled for FINS/UDP only.)
• Automatic generation (dynamic): Auto (dynamic)
• Automatic generation (static): Auto (Static)
• IP address table method: Table used
• Combined method: Mixed
Auto (dynamic)
Destination IP Address
(Change Dynamically)
Select to dynamically change the remote (destination) IP address for
FINS/UDP. To prohibit dynamic changes, deselect this box.
Checked
(Change Dynami-
cally)
IP Address Table
Set the IP address table that defines the relationship between FINS
node addresses and IP addresses.
With FINS/UDP, this is enabled only when the IP address table method
or combined method is set as the IP address conversion method.
None
Summary of Contents for CP1L-EL20DR-D
Page 3: ...CP1L EL20D CP1L EM30D CP1L EM40D CP1L EL EM CPU Unit Operation Manual Produced July 2017...
Page 4: ...iv...
Page 10: ...x...
Page 22: ...xxii...
Page 34: ...xxxiv Software Licenses and Copyrights 7...
Page 192: ...158 Trial Operation and Debugging Section 5 3...
Page 250: ...216 Automatic Clock Adjustment and Specifying Servers by Host Name Section 6 7...
Page 666: ...632 Trouble Shooting Section 11 7...
Page 696: ...662 Standard Models Appendix A...
Page 805: ...771 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 806: ...772 Connections to Serial Communications Option Boards Appendix F...
Page 836: ...802 PLC Setup Appendix G...
Page 838: ...804 TCP Status Transitions Appendix H...
Page 840: ...806 Ethernet Network Parameters Appendix I...
Page 842: ...808 Buffer Configuration CP1L EL EM Appendix J...
Page 844: ...810 Ethernet Specifications Appendix K...
Page 851: ...Index 817 work words 118 write protection 447...
Page 852: ...818 Index...
Page 854: ...820 Revision History...
Page 855: ......