611
LCD Option Board Function
Section 11-6
DM Area Settings
The text message is stored in the DM area. One character is 1 byte and one
DM word is 2 bytes, so 24 DM words need to be used to store one screen
message. But not all of the area can be used. Do not specify an address
between D10000 and D31999 for a CPU Unit with 20 I/O Points.
The following table shows the setting area for each screen when the leading
word address is D09000.
In this example, “Elevator Stop at 1F” is displayed on the Message Screen 2.
The data can be set in the DM area with the CX-Programmer.
The settings show as below.
Screen No.
Word
0
1
2
3
4
5
6
7
8
9
01
D09000
1
2
3
4
5
6
7
8
9
10
11
12
D09010
13
14
15
16
17
18
19
20
21
22
23
24
D09020
25
26
27
28
29
30
31
32
33
34
35
36
D09030
37
38
39
40
41
42
43
44
45
46
47
48
02
D09040
1
2
3
4
5
6
7
8
9
10
11
12
D09050
13
14
15
16
17
18
19
20
21
22
23
24
D09060
25
26
27
28
29
30
31
32
33
34
35
36
D09070
37
38
39
40
41
42
43
44
45
46
47
48
···
16
D09600
1
2
3
4
5
6
7
8
9
10
11
12
D09610
13
14
15
16
17
18
19
20
21
22
23
24
D09620
25
26
27
28
29
30
31
32
33
34
35
36
D09630
37
38
39
40
41
42
43
44
45
46
47
48
Line No.
Word
Setting
Character
1
D09040
2020
D09041
2020
D09042
2020
D09043
2020
D09044
2020
D09045
2020
2
D09050
456C
E
l
D09051
6576
e
v
D09052
6174
a
t
D09053
6F72
o
r
D09054
2020
D09055
2020
3
D09060
2053
S
D09061
746F
t
o
D09062
7020
p
D09063
6174
a
t
D09064
2031
1
D09065
4620
F
4
D09070
2020
D09071
2020
D09072
2020
D09073
2020
D09074
2020
D09075
2020
Do not use.
Summary of Contents for CP1L-EL20DR-D
Page 3: ...CP1L EL20D CP1L EM30D CP1L EM40D CP1L EL EM CPU Unit Operation Manual Produced July 2017...
Page 4: ...iv...
Page 10: ...x...
Page 22: ...xxii...
Page 34: ...xxxiv Software Licenses and Copyrights 7...
Page 192: ...158 Trial Operation and Debugging Section 5 3...
Page 250: ...216 Automatic Clock Adjustment and Specifying Servers by Host Name Section 6 7...
Page 666: ...632 Trouble Shooting Section 11 7...
Page 696: ...662 Standard Models Appendix A...
Page 805: ...771 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 806: ...772 Connections to Serial Communications Option Boards Appendix F...
Page 836: ...802 PLC Setup Appendix G...
Page 838: ...804 TCP Status Transitions Appendix H...
Page 840: ...806 Ethernet Network Parameters Appendix I...
Page 842: ...808 Buffer Configuration CP1L EL EM Appendix J...
Page 844: ...810 Ethernet Specifications Appendix K...
Page 851: ...Index 817 work words 118 write protection 447...
Page 852: ...818 Index...
Page 854: ...820 Revision History...
Page 855: ......