Auxiliary Area Allocations by Address
Appendix D
A99
14
IR/DR Opera-
tion between
Tasks
Retained
ON when index and data registers
are shared between all tasks.
OFF when separate index and data
registers are being used in each
task.
OFF: Inde-
pendent
ON: Shared
(default)
Retained
Retained
---
15
Timer/Counter
PV Refresh
Mode Flag
Indicates whether the CPU Unit is
operating in BCD mode or binary
mode.
OFF: BCD
mode
ON: Binary
mode
Retained
Retained
---
A100
to
A199
All
Error Log
Area
When an error has occurred, the
error code, error contents, and
error’s time and date are stored in
the Error Log Area. Information on
the 20 most recent errors can be
stored.
Each error record occupies 5 words;
the function of these 5 words is as
follows:
1) Error code (bits 0 to 15)
2) Error contents (bits 0 to 15)
3) Minutes (bits 8 to 15),
Seconds (bits 0 to 7)
4) Day of month (bits 8 to 15),
Hours (bits 0 to 7)
5) Year (bits 8 to 15),
Month (bits 0 to 7)
Errors generated by FAL(006) and
FALS(007) will also be stored in this
Error Log.
The Error Log Area can be reset
from the CX-Programmer.
If the Error Log Area is full (20
records) and another error occurs,
the oldest record in A100 to A104 will
be cleared, the other 19 records are
shifted down, and the new record is
stored in A195 to A199.
Error code
Error con-
tents:
Address of
Aux. Area
word with
details or
0000.
Seconds:
00 to 59, BCD
Minutes:
00 to 59, BCD
Hours:
00 to 23, BCD
Day of month:
01 to 31, BCD
Month:
01 to 12, BCD
Year:
00 to 99, BCD
Retained
Retained Refreshed
when error
occurs.
A500.14
A300
A400
A200
11
First Cycle
Flag
ON for one cycle after PLC operation
begins (after the mode is switched
from PROGRAM to RUN or MONI-
TOR, for example).
ON for the
first cycle
---
---
---
---
12
Step Flag
ON for one cycle when step execu-
tion is started with STEP(008). This
flag can be used for initialization pro-
cessing at the beginning of a step.
ON for the
first cycle
after execu-
tion of
STEP(008).
Cleared
---
---
---
14
Task Started
Flag
When a task switches from WAIT or
INI to RUN status, this flag will be
turned ON within the task for one
cycle only.
The only difference between this flag
and A200.15 is that this flag also
turns ON when the task switches
from WAIT to RUN status.
ON: ON for
first cycle
(including
transitions
from WAIT
and IN)
OFF: Other
Cleared
Cleared
---
---
15
First Task
Startup Flag
ON when a task is executed for the
first time. This flag can be used to
check whether the current task is
being executed for the first time so
that initialization processing can be
performed if necessary.
ON: First exe-
cution
OFF: Not
executable for
the first time
or not being
executed.
Cleared
---
---
---
Address
Name
Function
Settings
Status
after
mode
change
Status
at star-
tup
Write
timing
Related
flags, set-
tings
Words
Bits
Summary of Contents for CP1L-EL20DR-D
Page 3: ...CP1L EL20D CP1L EM30D CP1L EM40D CP1L EL EM CPU Unit Operation Manual Produced July 2017...
Page 4: ...iv...
Page 10: ...x...
Page 22: ...xxii...
Page 34: ...xxxiv Software Licenses and Copyrights 7...
Page 192: ...158 Trial Operation and Debugging Section 5 3...
Page 250: ...216 Automatic Clock Adjustment and Specifying Servers by Host Name Section 6 7...
Page 666: ...632 Trouble Shooting Section 11 7...
Page 696: ...662 Standard Models Appendix A...
Page 805: ...771 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 806: ...772 Connections to Serial Communications Option Boards Appendix F...
Page 836: ...802 PLC Setup Appendix G...
Page 838: ...804 TCP Status Transitions Appendix H...
Page 840: ...806 Ethernet Network Parameters Appendix I...
Page 842: ...808 Buffer Configuration CP1L EL EM Appendix J...
Page 844: ...810 Ethernet Specifications Appendix K...
Page 851: ...Index 817 work words 118 write protection 447...
Page 852: ...818 Index...
Page 854: ...820 Revision History...
Page 855: ......