706
Auxiliary Area Allocations by Address
Appendix D
A280
02
Pulse Output
0 Output
Amount Set
Flag
ON when the number of output
pulses for pulse output 0 has been
set with the PULS(886) instruction.
Cleared when operation starts or
stops.
OFF: No setting
ON: Setting made
---
---
Cleared
Refreshed
when the
PULS(886)
instruction
is exe-
cuted.
Refreshed
when pulse
output
stops.
---
03
Pulse Output
0 Output
Completed
Flag
ON when the number of output
pulses set with the PULS(886) or
PLS2(887) instruction has been out-
put through pulse output 0.
Cleared when operation starts or
stops.
OFF: Output not completed.
ON: Output completed.
---
---
Cleared
Refreshed
at the start
or comple-
tion of
pulse out-
put in inde-
pendent
mode.
---
04
Pulse Output
0 Output In-
progress Flag
ON when pulses are being output
from pulse output 0.
Cleared when operation starts or
stops.
OFF: Stopped
ON: Outputting pulses.
---
---
Cleared
Refreshed
when pulse
output
starts or
stops.
---
05
Pulse Output
0 No-origin
Flag
ON when the origin has not been
determined for pulse output 0 and
goes OFF when the origin has been
determined.
Turned ON when power is turned
ON.
Turned ON when operation starts.
OFF: Origin established.
ON: Origin not established.
---
---
Cleared
Refreshed
each cycle
during the
oversee-
ing pro-
cesses.
---
06
Pulse Output
0 At-origin
Flag
ON when the pulse output PV
matches the origin (0).
OFF: Not stopped at origin.
ON: Stopped at origin.
---
---
Cleared
Refreshed
each cycle
during the
oversee-
ing pro-
cesses.
---
07
Pulse Output
0 Output
Stopped Error
Flag
ON when an error occurred while
outputting pulses in the pulse output
0 origin search function.
The Pulse Output 0 Output Stop
Error code will be written to A444.
OFF: No error
ON: Stop error occurred.
---
---
Cleared
Refreshed
when ori-
gin search
starts.
Refreshed
when a
pulse out-
put stop
error
occurs.
---
A281
00
Pulse Output
1 Accel/Decel
Flag
This flag will be ON when pulses are
being output from pulse output 1
according to an ACC(888) or
PLS2(887) instruction and the output
frequency is being changed in steps
(accelerating or decelerating).
Cleared when operation starts or
stops.
OFF: Constant speed
ON: Accelerating or decelerating
---
---
Cleared
Refreshed
each cycle
during
oversee
process.
---
Address
Name
Function
Settings
Status
after
mode
change
Status
at star-
tup
Write
timing
Related
flags, set-
tings
Words
Bits
Summary of Contents for CP1L-EL20DR-D
Page 3: ...CP1L EL20D CP1L EM30D CP1L EM40D CP1L EL EM CPU Unit Operation Manual Produced July 2017...
Page 4: ...iv...
Page 10: ...x...
Page 22: ...xxii...
Page 34: ...xxxiv Software Licenses and Copyrights 7...
Page 192: ...158 Trial Operation and Debugging Section 5 3...
Page 250: ...216 Automatic Clock Adjustment and Specifying Servers by Host Name Section 6 7...
Page 666: ...632 Trouble Shooting Section 11 7...
Page 696: ...662 Standard Models Appendix A...
Page 805: ...771 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 806: ...772 Connections to Serial Communications Option Boards Appendix F...
Page 836: ...802 PLC Setup Appendix G...
Page 838: ...804 TCP Status Transitions Appendix H...
Page 840: ...806 Ethernet Network Parameters Appendix I...
Page 842: ...808 Buffer Configuration CP1L EL EM Appendix J...
Page 844: ...810 Ethernet Specifications Appendix K...
Page 851: ...Index 817 work words 118 write protection 447...
Page 852: ...818 Index...
Page 854: ...820 Revision History...
Page 855: ......