398
Quick-response Inputs
Section 8-2
CPU Units with 30 I/O
Points
The 6 input bits CIO 0.04 to CIO 0.09 can be used as quick-response inputs.
CPU Units with 40 I/O
Points
The 6 input bits CIO 0.04 to CIO 0.09 can be used as quick-response inputs.
Setting the Input Functions in the PLC Setup
Normally, bits CIO 0.04 to CIO 0.09 are used as normal inputs. When using
these inputs as quick-response inputs, use the CX-Programmer to change the
input’s setting in the PLC Setup.
COM
01
03
05
07
09
11
01
03
05
00
02
04
06
08
10
00
02
04
+
-
NC
Upper Terminal Block
(CPU Unit with
DC Power Supply)
CIO 1 inputs
CIO 0 inputs
Quick-response input 1
Quick-response input 3
Quick-response input 5
Quick-response input 2
Quick-response input 0
Quick-response input 4
COM
01
03
05
07
09
11
01
03
05
07
09
11
00
02
04
06
08
10
00
02
04
06
08
10
+
-
NC
Upper Terminal Block
(CPU Unit with
DC Power Supply)
CIO 1 inputs
CIO 0 inputs
Quick-response input 1
Quick-response input 3
Quick-response input 5
Quick-response input 2
Quick-response input 0
Quick-response input 4
Input terminal block
CPU Unit
Quick-response inputs
Word
Bit
CPU Units with
40 I/O Points
CPU Units with
30 I/O Points
CPU Units with
20 I/O Points
CIO 0
00
Normal input 0
Normal input 0
Normal input 0
---
01
Normal input 1
Normal input 1
Normal input 1
---
02
Normal input 2
Normal input 2
Normal input 2
---
03
Normal input 3
Normal input 3
Normal input 3
---
04
Normal input 4
Normal input 4
Normal input 4
Quick-response input 0
05
Normal input 5
Normal input 5
Normal input 5
Quick-response input 1
06
Normal input 6
Normal input 6
Normal input 6
Quick-response input 2
07
Normal input 7
Normal input 7
Normal input 7
Quick-response input 3
08
Normal input 8
Normal input 8
Normal input 8
Quick-response input 4
09
Normal input 9
Normal input 9
Normal input 9
Quick-response input 5
10
Normal input 10
Normal input 10
Normal input 10
---
11
Normal input 11
Normal input 11
Normal input 11
---
CIO 1
00 to 05
Normal input 12 to 17
Normal input 12 to 17
---
---
06 to 11
Normal input 18 to 23
---
---
---
Summary of Contents for CP1L-EL20DR-D
Page 3: ...CP1L EL20D CP1L EM30D CP1L EM40D CP1L EL EM CPU Unit Operation Manual Produced July 2017...
Page 4: ...iv...
Page 10: ...x...
Page 22: ...xxii...
Page 34: ...xxxiv Software Licenses and Copyrights 7...
Page 192: ...158 Trial Operation and Debugging Section 5 3...
Page 250: ...216 Automatic Clock Adjustment and Specifying Servers by Host Name Section 6 7...
Page 666: ...632 Trouble Shooting Section 11 7...
Page 696: ...662 Standard Models Appendix A...
Page 805: ...771 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 806: ...772 Connections to Serial Communications Option Boards Appendix F...
Page 836: ...802 PLC Setup Appendix G...
Page 838: ...804 TCP Status Transitions Appendix H...
Page 840: ...806 Ethernet Network Parameters Appendix I...
Page 842: ...808 Buffer Configuration CP1L EL EM Appendix J...
Page 844: ...810 Ethernet Specifications Appendix K...
Page 851: ...Index 817 work words 118 write protection 447...
Page 852: ...818 Index...
Page 854: ...820 Revision History...
Page 855: ......