393
Interrupt Functions
Section 8-1
Range Comparison Table
The range comparison table requires a continuous block of 40 words because
comparison conditions 1 to 8 require 5 words each (2 words for the upper
range value, 2 words for the lower range value, and one word for the interrupt
task number).
Note
Always set the upper limit greater than or equal to the lower limit in each
range.
MODE CONTROL
Instruction: INI(880)
INI(880) can be used to start/stop comparison with the high-speed counter’s
comparison table, change the high-speed counter’s PV, change the PV of
interrupt inputs in counter mode, and control the pulse output functions.
Number of target values
Target value 1 (rightmost digits)
Target value 1 (leftmost digits)
Task number for target value 1
0001 to 0030 hex (1 to 48 target values)
0000 0000 to FFFF FFFF hex
Target value 48 (rightmost digits)
Target value 48 (leftmost digits)
Task number for target value 48
0000 0000 to FFFF FFFF hex
Interrupt task number
Direction
0: Incrementing
1: Decrementing
Interrupt task number
00 to FF hex (0 to 255)
Range 1 lower value (rightmost)
Range 1 lower value (leftmost
Task number for range 1
0000 0000 to FFFF FFFF hex (see note)
Range 1 upper value (rightmost)
Range 1 upper value (leftmost
0000 0000 to FFFF FFFF hex (see note)
Range 8 lower value (rightmost)
Range 8 lower value (leftmost
Task number for range 8
0000 0000 to FFFF FFFF hex (see note)
Range 8 upper value (rightmost)
Range 8 upper value (leftmost
0000 0000 to FFFF FFFF hex (see note)
Interrupt task number: 0000 to 00FF hex (0 to 255)
AAAA hex: Do not start interrupt task
FFFF hex: Disables that range’s settings.
@INI (880)
P
C
NV
Execution condition
P: Port specifier
NV: First word of new PV
C: Control data
Summary of Contents for CP1L-EL20DR-D
Page 3: ...CP1L EL20D CP1L EM30D CP1L EM40D CP1L EL EM CPU Unit Operation Manual Produced July 2017...
Page 4: ...iv...
Page 10: ...x...
Page 22: ...xxii...
Page 34: ...xxxiv Software Licenses and Copyrights 7...
Page 192: ...158 Trial Operation and Debugging Section 5 3...
Page 250: ...216 Automatic Clock Adjustment and Specifying Servers by Host Name Section 6 7...
Page 666: ...632 Trouble Shooting Section 11 7...
Page 696: ...662 Standard Models Appendix A...
Page 805: ...771 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 806: ...772 Connections to Serial Communications Option Boards Appendix F...
Page 836: ...802 PLC Setup Appendix G...
Page 838: ...804 TCP Status Transitions Appendix H...
Page 840: ...806 Ethernet Network Parameters Appendix I...
Page 842: ...808 Buffer Configuration CP1L EL EM Appendix J...
Page 844: ...810 Ethernet Specifications Appendix K...
Page 851: ...Index 817 work words 118 write protection 447...
Page 852: ...818 Index...
Page 854: ...820 Revision History...
Page 855: ......