243
Pulse Outputs
Section 7-2
Auxiliary Area Data Allocation
Function
Pulse output number
0
1
Pulse output PV storage words
PV range: 8000 0000 to 7FFF FFFF hex
(
−
2,147,483,648 to 2,147,483,647)
Leftmost 4 digits
A277
A279
Rightmost 4 digits
A276
A278
Reset Bits
The pulse output PV will be cleared when this bit is
turned from OFF to ON.
0: Not cleared.
1: Clear PV.
A540.00
A541.00
CW Limit Input Signal Flags
This is the CW limit input signal, which is used in the
origin search.
ON when turned ON from an external
input.
A540.08
A541.08
CCW Limit Input Signal Flags
This is the CCW limit input signal, which is used in
the origin search.
ON when turned ON from an external
input.
A540.09
A541.09
Positioning completed input signals
This is the positioning completed input signal, which
is used in the origin search.
ON when turned ON from an external
input.
A540.10
A541.10
Accel/Decel Flags
ON when pulses are being output according to an
ACC(888) or PLS2(887) instruction and the output
frequency is being changed in steps (accelerating or
decelerating).
0: Constant speed
1: Accelerating or decelerating
A280.00
A281.00
Overflow/Underflow Flags
ON when an overflow or underflow has occurred in
the pulse output PV.
0: Normal
1: Overflow or underflow
A280.01
A281.01
Output Amount Set Flags
ON when the number of output pulses has been set
with the PULS instruction.
0: No setting
1: Setting made
A280.02
A281.02
Output Completed Flags
ON when the number of output pulses set with the
PULS(886)/PLS2(887) instruction has been output.
0: Output not completed.
1: Output completed.
A280.03
A281.03
Output In-progress Flags
ON when pulses are being output from the pulse
output.
0: Stopped
1: Outputting pulses.
A280.04
A281.04
No-origin Flags
ON when the origin has not been determined for the
pulse output.
0: Origin established.
1: Origin not established.
A280.05
A281.05
At-origin Flags
ON when the pulse output PV matches the origin
(0).
0: Not stopped at origin.
1: Stopped at origin.
A280.06
A281.06
Output Stopped Error Flags
ON when an error occurred while outputting pulses
in the origin search function.
0: No error
1: Stop error occurred.
A280.07
A281.07
Stop Error Codes
When a Pulse Output Stop Error occurs, the error
code is stored in that pulse outputs corresponding
Stop Error Code word.
---
A444
A445
Summary of Contents for CP1L-EL20DR-D
Page 3: ...CP1L EL20D CP1L EM30D CP1L EM40D CP1L EL EM CPU Unit Operation Manual Produced July 2017...
Page 4: ...iv...
Page 10: ...x...
Page 22: ...xxii...
Page 34: ...xxxiv Software Licenses and Copyrights 7...
Page 192: ...158 Trial Operation and Debugging Section 5 3...
Page 250: ...216 Automatic Clock Adjustment and Specifying Servers by Host Name Section 6 7...
Page 666: ...632 Trouble Shooting Section 11 7...
Page 696: ...662 Standard Models Appendix A...
Page 805: ...771 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 806: ...772 Connections to Serial Communications Option Boards Appendix F...
Page 836: ...802 PLC Setup Appendix G...
Page 838: ...804 TCP Status Transitions Appendix H...
Page 840: ...806 Ethernet Network Parameters Appendix I...
Page 842: ...808 Buffer Configuration CP1L EL EM Appendix J...
Page 844: ...810 Ethernet Specifications Appendix K...
Page 851: ...Index 817 work words 118 write protection 447...
Page 852: ...818 Index...
Page 854: ...820 Revision History...
Page 855: ......