3. Disconnect the electrical connector (D).
4. Remove the top nut (C) and remove the sensor (B).
5. Remove the top nut from the new sensor and position
the sensor into the support. Secure with top nut (C).
6. Adjust the gap between the sensor disc (A) and the
sensor (B) to 1/8 in. (3 mm) using nut (C).
7. Connect to harness at (D).
IMPORTANT:
Ensure the sensor electrical harness does NOT
contact the chain or sprocket.
8. Reinstall the drive cover. Refer to
Figure 5.283: Speed Sensor
Replacing Lexion 400 Series Sensor
DANGER
To avoid bodily injury or death from unexpected start-up of machine, always stop engine and remove key
from ignition before leaving operator’s seat for any reason.
1. Shut down the combine, and remove the key from
the ignition.
2. Remove the drive cover. Refer to
3. Disconnect the electrical connector (C).
4. Remove the top nuts (D) and remove the sensor (B).
5. Remove the top nut from the new sensor and position
the sensor into the support. Secure with top nut (D).
6. Adjust the gap between the sensor disc (A) and the
sensor (B) to 1/8 in. (3 mm) using nuts (D).
7. Connect to harness at (C).
IMPORTANT:
Ensure the sensor electrical harness does NOT
contact the chain or sprocket.
8. Reinstall the drive cover. Refer to
Figure 5.284: Speed Sensor
Replacing Lexion 500/700 Series Sensor
DANGER
To avoid bodily injury or death from unexpected start-up of machine, always stop engine and remove key
from ignition before leaving operator’s seat for any reason.
147831
439
Revision A
Summary of Contents for FlexDraper FD1 Series
Page 2: ...FD1 Series FlexDraper Header for Combines Published April 2016 ...
Page 3: ...Declaration of Conformity 147831 i Revision A ...
Page 4: ...147831 ii Revision A ...
Page 5: ...147831 iii Revision A ...
Page 6: ...147831 iv Revision A ...
Page 8: ......
Page 10: ......
Page 34: ......
Page 40: ...PRODUCT OVERVIEW Figure 2 1 Header Width 147831 22 Revision A ...
Page 462: ......
Page 484: ......
Page 508: ......
Page 509: ......