2. Select HEADER (A), and press ENTER. The
CALIBRATION dialog box opens.
NOTE:
You can use the up and down navigation keys to
move between options.
Figure 3.292: New Holland Combine Display
3. Follow the calibration steps in the order in which they
appear in the dialog box. As you proceed through
the calibration process, the display will automatically
update to show the next step.
NOTE:
Pressing the ESC key during any of the steps
or letting the system sit idle for more than three
minutes will cause the calibration procedure
to stop.
NOTE:
Refer to your combine operator’s manual for an
explanation of any error codes.
Figure 3.293: New Holland Combine Display
4. When all steps have been completed, CALIBRATION
SUCCESSFUL message is displayed on the page. Exit
the CALIBRATION menu by pressing the ENTER or
ESC key.
NOTE:
If
fl
oat was set heavier to complete ground
calibration procedure, adjust to recommended
operating
fl
oat after the calibration is complete.
5. If the unit does not function properly, conduct the
maximum stubble height calibration.
Calibrating Maximum Stubble Height
This procedure describes how to calibrate the area counter to stop or start counting at the correct height. Program
the header to a height that will never be reached while cutting. The area counter will stop counting when the
header is above the programmed height, and will begin counting when the header is below the programmed height.
Select the height of the header that corresponds to the description above.
147831
185
Revision A
Summary of Contents for FlexDraper FD1 Series
Page 2: ...FD1 Series FlexDraper Header for Combines Published April 2016 ...
Page 3: ...Declaration of Conformity 147831 i Revision A ...
Page 4: ...147831 ii Revision A ...
Page 5: ...147831 iii Revision A ...
Page 6: ...147831 iv Revision A ...
Page 8: ......
Page 10: ......
Page 34: ......
Page 40: ...PRODUCT OVERVIEW Figure 2 1 Header Width 147831 22 Revision A ...
Page 462: ......
Page 484: ......
Page 508: ......
Page 509: ......