9. Select LEFT HEADER HEIGHT SEN (A), and then
select the GRAPH button (B). The exact voltage is
displayed at top of page. Raise and lower the header
to see the full range of voltage readings.
10. If the sensor voltage is not within the low and high
limits or, if the range between the low and high limits is
insuf
fi
cient, adjust the voltage limits. Refer to
Voltage Limits (One-Sensor System), page 106
.
Figure 3.155: Case IH Combine Display
Calibrating the Auto Header Height Control (Case IH 5130/6130/7130, 7010/8010;
7120/8120/9120; 7230/8230/9230)
For best performance from the auto header height control (AHHC), perform these procedures with the center-link
set to D. When setup and calibration are complete, adjust the center-link back to desired header angle. Refer to
.
NOTE:
This procedure applies to combines with a software version below 28.00. For instructions on calibrating the AHHC
for combines with software version 28.00 or above, refer to
Calibrating the Auto Header Height Control (Case
Combines with Version 28.00 or Higher Software), page 120
NOTE:
Changes may have been made to the combine controls or display since this document was published. Refer to
the combine operator’s manual for updates.
1. Ensure center-link is set to D.
2. Ensure all header and
fl
oat module electrical and
hydraulic connections are made.
3. Select TOOLBOX on the MAIN page, and then
select HEADER.
4. Set appropriate HEADER STYLE.
Figure 3.156: Case IH Combine Display
147831
118
Revision A
Summary of Contents for FlexDraper FD1 Series
Page 2: ...FD1 Series FlexDraper Header for Combines Published April 2016 ...
Page 3: ...Declaration of Conformity 147831 i Revision A ...
Page 4: ...147831 ii Revision A ...
Page 5: ...147831 iii Revision A ...
Page 6: ...147831 iv Revision A ...
Page 8: ......
Page 10: ......
Page 34: ......
Page 40: ...PRODUCT OVERVIEW Figure 2 1 Header Width 147831 22 Revision A ...
Page 462: ......
Page 484: ......
Page 508: ......
Page 509: ......