Removing Endshields
1. Fully open endshield. Refer to
.
2. Engage lock (A) to prevent endshield movement.
3. Remove self-tapping screw (B).
4. Slide endshield upwards and remove from hinge arm.
5. Place endshield away from work area.
Figure 3.12: Left Endshield
Installing Endshields
1. Guide endshield onto hinge arm and slowly slide
it downwards.
2. Install self-tapping screw (B).
3. Disengage lock (A) to allow endshield movement.
4. Close endshield. Refer to
NOTE:
Endshields may expand or contract when
subjected to large temperature changes. Top pin
and lower latch bracket positions can be adjusted
to compensate for dimensional changes. Refer
to
Checking and Adjusting Endshields, page 34
.
Figure 3.13: Left Endshield
147831
33
Revision A