Adjusting Voltage Limits (Two-Sensor System)
DANGER
To avoid bodily injury or death from unexpected start-up of machine, always stop engine and remove key
from ignition before leaving operator’s seat for any reason.
1. Extend guard angle fully; the header angle indicator should be at D.
2. Position header 6–10 in. above the ground; the
fl
oat indicator should be at 0.
3. Adjust left-hand sensor voltage:
a. Loosen sensor mounting nuts (A).
b. Rotate sensor counterclockwise to lower the
voltage.
Rotate sensor clockwise to raise the
voltage.
c. Check that the left-hand sensor is at the correct
upper voltage limit according to Table
Combine Voltage Limits, page 101
d. Tighten sensor mounting nuts.
Figure 3.136: Optional Two Sensor Kit –
LH Sensor
147831
108
Revision A