1. Complete the following steps to adjust the upper
voltage limit:
a. Extend guard angle fully; the header angle
indicator should be at D.
b. Position header 6–10 in. above the ground; the
fl
oat indicator should be at the 0.
c. Check the upper voltage limit using the combine
display or voltmeter. Refer to Table
.
d. Loosen sensor mounting nuts (A).
e. Rotate sensor (B) counterclockwise to increase
high voltage limit and clockwise to decrease it.
f.
Tighten sensor mounting nuts (A).
2. Complete the following steps to adjust the lower
voltage limit:
a. Extend guard angle fully; the header angle
indicator should be at D.
b. Fully lower header on the ground; the
fl
oat
indicator should be at 4.
c. Check the lower voltage limit using the combine
display or voltmeter. Refer to Table
.
d. Loosen sensor mounting nuts (A).
e. Rotate sensor counterclockwise to increase low
voltage limit and clockwise to decrease it.
f.
Tighten sensor mounting nuts (A).
3. After making adjustments, recheck both the upper
and lower voltage limits to make sure they are within
the required range according to Table
.
Figure 3.134: AHHC Sensor Assembly
4. If unable to get the voltage within the required
range, loosen mounting bolts (A) and shift sensor
assembly (B) inboard (right as shown in Figure
AHHC Sensor Assembly, page 107
NOTE:
If sensor assembly is shifted right or left, it may
be necessary to repeat steps 1 and 2 to achieve
the proper voltage limits.
Figure 3.135: AHHC Sensor Assembly
147831
107
Revision A
Summary of Contents for FlexDraper FD1 Series
Page 2: ...FD1 Series FlexDraper Header for Combines Published April 2016 ...
Page 3: ...Declaration of Conformity 147831 i Revision A ...
Page 4: ...147831 ii Revision A ...
Page 5: ...147831 iii Revision A ...
Page 6: ...147831 iv Revision A ...
Page 8: ......
Page 10: ......
Page 34: ......
Page 40: ...PRODUCT OVERVIEW Figure 2 1 Header Width 147831 22 Revision A ...
Page 462: ......
Page 484: ......
Page 508: ......
Page 509: ......