9. Select GRAPH (A). The exact voltage (B) is displayed
at the top of the page.
10. Raise and lower the header to see the full range of
voltage readings.
11. If the sensor voltage is not within the low and high
limits, or if the range between the low and high limits is
insuf
fi
cient, adjust the voltage limits. Refer to
Voltage Limits (One-Sensor System), page 106
.
Figure 3.310: New Holland Combine Display
Engaging the Auto Header Height Control (New Holland CR Series)
This procedure applies only to 2015 and later CR models (6.80, 6.90, 7.90, 8.90, 9.90, and 10.90).
For best performance of the auto header height control (AHHC), perform these procedures with the center-link set
to D. When setup and calibration are complete, adjust the center-link back to desired header angle.
NOTE:
Changes may have been made to the combine controls or display since this document was published. Refer to
the combine operator’s manual for updates.
1. Ensure center-link is set to D.
2. Select TOOLBOX (A) on the main page.
The
TOOLBOX page displays.
Figure 3.311: New Holland Combine Display
147831
194
Revision A
Summary of Contents for FlexDraper FD1 Series