Manually Checking Voltage Range (Two-Sensor System)
FM100
fl
oat modules equipped with the optional
two-sensor system will have a left- and right-hand sensor
located on the back frame of the
fl
oat module.
To manually check the sensor’s output voltage range,
follow these steps:
1. Position the header 6 in. (150 mm) above the ground,
and unlock the
fl
oat module
fl
oat.
Figure 3.128: Optional Two-Sensor System
2. Check that
fl
oat lock linkage is on down stops (washer
[A] cannot be moved) at both locations.
NOTE:
If the header is not on down stops during the next
two steps, the voltage may go out of range during
operation causing a malfunction of the AHHC system.
Figure 3.129: Float Lock
147831
104
Revision A