Appendix 2 Standard PLC Function Configuration
451
Appendix
Appendix 2.2.1 High speed I/O interface
Fig. 2-5 Pins of CN61
Corresponding
connector pins
PLC
address
Function defined by
the standard PLC addresses
Note
CN61.1 0V
CN61.2
X0.0
Reserved
CN61.3
X0.1
Reserved
CN61.4
X0.2
Reserved
CN61.5
X0.3
Reserved
CN61.6
X0.4
SKIP
G31 skip signal
CN61.7
X0.5
ESP
Emergency stop input signal
CN61.8
X0.6
G36
G36 skip signal
CN61.9
X0.7
G37
G37 skip signal
CN61.10 0V
Appendix 2.2.2 Common machine I/O interface
The all-purpose output/input of the GSK988TA/988TA1/988TB is distributed by connecting the
I/O unit with the GSKLink. Up to 4 I/O units can be connected by GSKLink, up to 48 input points and
32 output points of each I/O unit, and the address use range is X80~X127 and Y80~Y127 of which
the user should configure the system address by herself/himself.
An I/O unit with 48 input points and 32 output points is configured in the standard configuration of
the GSK988TA/988TA1/988TB system. The configuration address of standard ladder diagram in the
system is X100~X105 and Y100~Y103. The overall I/O introduced in this User Manual, however, if
the difference condition occurs, refer to the User Manual offered by machine tool manufacturer. The
signal addresses are subject to it.
PLC address
Function defined by standard PLC address
Remark
X100.0
SAGT
Protection door detection signal
X100.1
Reserved
X100.2
DIQP
Chuck input signal
X100.3
The
1
st
axis deceleration signal
X100.4
DITW
Tailstock control signal
Summary of Contents for GSK988TA
Page 6: ...GSK988TA GSK988TA1 GSK988TB Turning Center CNC System User Manual Programming Operation VI ...
Page 19: ...1 Ⅰ Programming PROGRAMMING ...
Page 227: ...209 Ⅱ Operation OPERATION ...
Page 369: ...Chater 10 Machining Example 351 Ⅱ Operation ...
Page 371: ...353 Appendix ...
Page 465: ...Appendix 1 Parameters 447 Appendix ...
Page 479: ...Appendix 3 Interface Explanation 461 Appendix ...
Page 527: ...Appendix 5 Installation Layout 509 Appendix ...