GSK988TA/GSK988TA1/GSK988TB Turning Center CNC System User Manual
【
Programming & Operation
】
462
Appendix
Appendix 4 Alarm Troubleshooting
Appendix 4.1 CNC Common Alarm Remedy
Alarm
No.
Meaning
Possible Alarm Reason
Troubleshooting
1. Whether the ESP button is
controlled
Modify the parameter or
check the connection
2. Incorrect wiring
3. The setting of bit 7 of
parameter 3003 (ESP) is
inconsistent with the actual
connection.
000
Emergency stop,
ESP open circuit
4. The setting of parameter K10.7
is inconsistent with the actual
connection.
001
Part program open
failure
Program is not downloaded
before the running in AUTO
mode.
Reset to clear alarm and
re-execute the program
002
Part prog. segment
loading failure
Error found in loading segment
when executing MDI prog. or
checking syntax
010
Single block
exceeds 256
characters
Characters excessive in single
block
011
Data exceeds
permissive range
Input data exceeds permissive
range or the specified data
exceeds 8 digits
012
Address not found
With number or symbol other
than address at the beginning of
a block
013
No data follows
address
No data follows address or
expression format following
address checks error, without
brackets
014
Illegal use of
negative sign
Sign "-" was input after an
address with which it can't be
used, or two or more "-" was input
015
Illegal use of
decimal point
Decimal point"." was input after
an address with which it can't be
use, or two or more "." was input
016
Input illegal address Input unusable address in
significant area
017
Incorrect G code
Specify improper G code or that
with functions not provided
018
Address repetition
error
Specify the same address twice
or more in a block Or specify two
or more G codes in same group
in a block. Refer to para. 3403#6
AD2.
Summary of Contents for GSK988TA
Page 6: ...GSK988TA GSK988TA1 GSK988TB Turning Center CNC System User Manual Programming Operation VI ...
Page 19: ...1 Ⅰ Programming PROGRAMMING ...
Page 227: ...209 Ⅱ Operation OPERATION ...
Page 369: ...Chater 10 Machining Example 351 Ⅱ Operation ...
Page 371: ...353 Appendix ...
Page 465: ...Appendix 1 Parameters 447 Appendix ...
Page 479: ...Appendix 3 Interface Explanation 461 Appendix ...
Page 527: ...Appendix 5 Installation Layout 509 Appendix ...