GSK988TA/GSK988TA1/GSK988TB Turning Center CNC System User Manual
【
Programming & Operation
】
40
Ⅰ
Programming
Note: the tool nose radius compensation is applied to only arc.
2.6 Dwell G04
Command function:
it can delay the next block to execute in the defined time.
Command format:
G04 P__
;
or
G04 X__
;
or
G04 U__
;
or
G04
;
Code specification:
G04 is non-modal.
The dwell time is defined by the word P__, X__ or U__.
X, U value can specify the decimal.
P value cannot have the decimal, otherwise, the system alarms.
Time of P__, X__ or U__ is shown below.
Address
P U
X
DWT=1 0.001s
ISB 0.001s
Unit
DWT=0
ISC 0.0001s
s s
Note: DWT is the setting value of No. 1015 Bit 7(DWT).
Value range of P__, X__ or U__ is shown below.
Address Incremental system
Metric input
Inch input
ISB system
-99999.999
~
99999.999
-9999.9999
~
9999.9999
X, U
ISC system
-9999.9999
~
9999.9999
-999.99999
~
999.99999
P ISB,
ISC
0~99999999
0~99999999
Note 1: The system exactly stop between blocks when P, X, U are not input or zero is specified..
Note 2: P cannot code a negative value, otherwise, an alarm occurs.
Note 3: P time unit is set by No. 1015 Bit 7(DWT).
Summary of Contents for GSK988TA
Page 6: ...GSK988TA GSK988TA1 GSK988TB Turning Center CNC System User Manual Programming Operation VI ...
Page 19: ...1 Ⅰ Programming PROGRAMMING ...
Page 227: ...209 Ⅱ Operation OPERATION ...
Page 369: ...Chater 10 Machining Example 351 Ⅱ Operation ...
Page 371: ...353 Appendix ...
Page 465: ...Appendix 1 Parameters 447 Appendix ...
Page 479: ...Appendix 3 Interface Explanation 461 Appendix ...
Page 527: ...Appendix 5 Installation Layout 509 Appendix ...