GSK988TA/GSK988TA1/GSK988TB Turning Center CNC System User Manual
【
Programming & Operation
】
386
Appendix
control I/O unit 1.
3052
The logic ID number (IOID2) of system control I/O unit 2
『
Modification authority
』
: Machine
『
Value Range
』:
0,100~110
『
Default Setting
』:
0
Set the logic ID number (0 means that this I/O unit disconnects with the GSKLink) of the system
control I/O unit 2.
3053
The logic ID number (IOID3) of system control I/O unit 3
『
Modification authority
』
: Machine
『
Value Range
』:
0,100~110
『
Default Setting
』:
0
Set the logic ID number (0 means that this I/O unit disconnects with the GSKLink) of the system
control I/O unit 3.
3054
The logic ID number (IOID4) of system control I/O unit 4
『
Modification authority
』
: Machine
『
Value Range
』:
0,100~110
『
Default Setting
』:
0
Set the logic ID number (0 means that this I/O unit disconnects with the GSKLink) of the system
control I/O unit 4.
3060
The logic ID number (GWID) of the system gateway control
『
Modification authority
』
: Machine
『
Value Range
』:
0,200~254
『
Default Setting
』:
0
This parameter setting system controls the logic ID number of the gateway. (0 means not use the
gateway
#7 #6 #5 #4 #3 #2 #1 #0
3061
GWP
GWC
『
Modification authority
』
: Machine
『
Validate method
』
: After power-on
『
Parameter Type
』:
Bit
『
Default Setting
』:
0000 0000
Summary of Contents for GSK988TA
Page 6: ...GSK988TA GSK988TA1 GSK988TB Turning Center CNC System User Manual Programming Operation VI ...
Page 19: ...1 Ⅰ Programming PROGRAMMING ...
Page 227: ...209 Ⅱ Operation OPERATION ...
Page 369: ...Chater 10 Machining Example 351 Ⅱ Operation ...
Page 371: ...353 Appendix ...
Page 465: ...Appendix 1 Parameters 447 Appendix ...
Page 479: ...Appendix 3 Interface Explanation 461 Appendix ...
Page 527: ...Appendix 5 Installation Layout 509 Appendix ...