Chapter 6 Auto Operation
307
Ⅱ
Operation
The key
on MDI panel is pressed or M30 command is executed by DNC program,
running ends and the system enters the resetting status, which is shown as Fig.6-8:
Fig.6-8
Note: In DNC program, the program calling and the program skip commands can’t be executed.
6.4 Automatic Running Status Control
6.4.1 Machine Lock and the Miscellaneous Lock
When the tool isn’t moved, while the coordinate position changing is displayed, the machine lock
function is used. After using the function, all axes are locked and all axes movements are stopped.
Except for that, M, S and T commands are locked by the miscellaneous function. And it is same as
the machine tool locked to check the program.
6.4.1.1 The Machine Lock
When the machining program is executed, while the machine remains still, only the tool position
change is displayed, the machine can be locked to check the program. When the machine is locked,
all axes movements are stopped.
Press the machine locked switch
on the operation panel. The machine isn’t moved while
each axis position on the monitor is being changed. About the machine locked, please refer to the
user manual from the machine tool builder.
Note 1: During automatic running, the position relation between the workpiece coordinate system and the
machine coordinate system may be different before and after the machine locked. Then, the
command can be set by the coordinate or the workpiece coordinate system can be confirmed with
the manual reference position return.
Note 2: When the machine is locked, G28 or G30 command is sent, although the command is received, the
tool can’t return the reference position and the reference position return indicator lamp is OFF.
Summary of Contents for GSK988TA
Page 6: ...GSK988TA GSK988TA1 GSK988TB Turning Center CNC System User Manual Programming Operation VI ...
Page 19: ...1 Ⅰ Programming PROGRAMMING ...
Page 227: ...209 Ⅱ Operation OPERATION ...
Page 369: ...Chater 10 Machining Example 351 Ⅱ Operation ...
Page 371: ...353 Appendix ...
Page 465: ...Appendix 1 Parameters 447 Appendix ...
Page 479: ...Appendix 3 Interface Explanation 461 Appendix ...
Page 527: ...Appendix 5 Installation Layout 509 Appendix ...