8.2 Path Graph Display and Operation
The tool path can be real-time checked with the graph path display.
(
1
)
Press
function key to enter the graph page set;
(
2
)
On the graph page set, press
software key to enter the path display page and
the program path currently executed is displayed, which is shown as Fig. 8-2:
Fig.8-2
In the figure, the current displayed coordinate plane and the path graph magnification are
displayed below the path display screen. On the graph top, the current system running mode and
status are displayed, on the screen right side, the current absolute coordinate value, the relative
coordinate value and the modal command are displayed.
The path graph is operated as below:
(
1
)
Press
,
software key to scale up/down the path graph and the
previous path graph is cleared;
(
2
)
Press
software key to clear the screen path;
(
3
)
Press
software key to restore the path graph into the original normal position,
and the previous path graph is cleared.
(
4
)
Respectively press
,
,
and
keys to move the path graph
upward/downward/leftward/rightward.
Note 1: The name of each axis is set by the parameter #1020, and each axis is set as the different names
with the letters, and then, on the path display page, the name of each coordinate plane and that of
the path coordinate can be switched correspondingly.
2. The system is only with the front and back tool posts without the left and right ones, so the
horizontal axis can only be set as Z axis of the basic one.
Summary of Contents for GSK988TA
Page 6: ...GSK988TA GSK988TA1 GSK988TB Turning Center CNC System User Manual Programming Operation VI ...
Page 19: ...1 Ⅰ Programming PROGRAMMING ...
Page 227: ...209 Ⅱ Operation OPERATION ...
Page 369: ...Chater 10 Machining Example 351 Ⅱ Operation ...
Page 371: ...353 Appendix ...
Page 465: ...Appendix 1 Parameters 447 Appendix ...
Page 479: ...Appendix 3 Interface Explanation 461 Appendix ...
Page 527: ...Appendix 5 Installation Layout 509 Appendix ...