Appendix 1 Parameters
355
Appendix
Appendix 1.1 Parameter for “Setting”
#7 #6 #5 #4 #3 #2 #1 #0
0000 SEQ INI
『
Modification authority
』
: Equipment management
『
Default Setting
』
: 0000 0000
#2 INI Input unit
0: Metric system
1: Inch system
#5 SEQ whether insert the sequence number automatically
0: No
1: Yes
Note: In EDIT or MDI mode, sequence number can be inserted automatically. The
incremental value of sequence number is set in parameter of NO.3216.
Appendix 1.2 Parameters of the Interfaces of Input and Output
0123
Serial port baud rate (BPS)
『
Modification authority
』
:Equipment management
『
Value Range
』
: 4800, 9600, 19200, 38400, 57600, 115200
『
Defualt Setting
』
: 115200
#7 #6 #5 #4 #3 #2 #1 #0
0138
OWN
『
Modification authority
』
: Equipment management
『
Default Setting
』
: 0000 0000
#6 OWN When NC Value or the programs are input or output,:
0: whether the covered file information is displayed
1: covered file, is not displayed
Note 1: The
『
Data Range
』
of bit type parameters is 0 or 1.
Note 2: When
『
Validate method
』
is not stated, the parameter will become
valid immediately.
Note 3: When
『
Parameter Type
』
is not stated, the parameter is of bit type or
word type.
Summary of Contents for GSK988TA
Page 6: ...GSK988TA GSK988TA1 GSK988TB Turning Center CNC System User Manual Programming Operation VI ...
Page 19: ...1 Ⅰ Programming PROGRAMMING ...
Page 227: ...209 Ⅱ Operation OPERATION ...
Page 369: ...Chater 10 Machining Example 351 Ⅱ Operation ...
Page 371: ...353 Appendix ...
Page 465: ...Appendix 1 Parameters 447 Appendix ...
Page 479: ...Appendix 3 Interface Explanation 461 Appendix ...
Page 527: ...Appendix 5 Installation Layout 509 Appendix ...