Appendix 1 Parameters
369
Appendix
Respectively set the positive and negative boundary coordinate values in stroke detection 1
along each axis in memory type in the machine coordinate system. Set outside of the boundary as the
restricted area. When parameter LMS (No.1300#2) is “1”, and the stroke limit switching signal EXLM
(G7.6) in memory type is “1”, the restricted area is valid, but it is invalid if it is set by No.1320 and
1321.
1. The axes programmed by the diameter must be set by the diameter value.
2. The parameter is invalid when parameter LMS (No.1320#2) is “0”, or the stroke limit
switching signal EXLM (G7.6) in the memory type is “0”. Then, the restricted area set by
parameter No.1320 or No. 1321 is valid.
Appendix 1.6 Parameter of the Feedrate
#7 #6 #5 #4 #3 #2 #1 #0
1401 RDR
TDR
RF0 LRP
RPD
『
Modification authority
』
: Equipment management
『
Default Setting
』:
0000 0000
#0 RPD Manually rapid run from power on to the reference point return
0: Invalid (JOG speed)
1: Valid
#1 LRP Positioning (G00):
0
:
Non-linear interpolation positioning
1
:
Linear interpolation positioning
#4 RF0 When the cutting feedrate override is 0% during rapid traverse
0: tool does not stop moving
1: tool stops moving
#5 TDR During thread cutting or tapping, dry run is:
0: Valid
1: Invalid
#6 RDR To rapid traverse command, dry run is:
0: Invalid
1: valid
#7 #6 #5 #4 #3 #2 #1 #0
1402
JOV
『
Modification authority
』
: Equipment management
Summary of Contents for GSK988TA
Page 6: ...GSK988TA GSK988TA1 GSK988TB Turning Center CNC System User Manual Programming Operation VI ...
Page 19: ...1 Ⅰ Programming PROGRAMMING ...
Page 227: ...209 Ⅱ Operation OPERATION ...
Page 369: ...Chater 10 Machining Example 351 Ⅱ Operation ...
Page 371: ...353 Appendix ...
Page 465: ...Appendix 1 Parameters 447 Appendix ...
Page 479: ...Appendix 3 Interface Explanation 461 Appendix ...
Page 527: ...Appendix 5 Installation Layout 509 Appendix ...