Appendix
value based upon the T code numerical value becomes the tool group number of the tool life-span
administration.
6811
The M code is used by tool life-span counting restart (MRN)
『
Default Setting
』:
0
『
Modification authority
』
: Equipment management
『
Value Range
』:
0
~
127
『
Validate method
』:
Immediately
In this case, the life-span existence is set by times, the tool group when the tool life-span
counting restarting specifies the M code is used up.
The tool-change signal (TLCH) may also be output even if only one signal; when it is set to 0, the
parameter will then be ignored.
6813
The Max. group number of the tool life-span administration (MTN)
『
Default Setting
』:
0
『
Modification authority
』
: Equipment management
『
Value Range
』:
0, 8, 16, 32, 64, 128
『
Validate method
』
: After power-on
Set the used top group number of each path, after this parameter is set, the power should be
temporarily turned off.
6844
The residual span using times of tool (TLP)
『
Default Setting
』:
0
『
Modification authority
』
: Equipment management
『
Value Range
』:
0~65535
『
Validate method
』:
Immediately
In the case of the tool life-span is specified, cutter output span reaches to the tool residual span
of the predictive signal (Using times).
6845
The remainder span using time of tool (TLR)
『
Default Setting
』:
0
『
Modification authority
』
: Equipment management
『
Value Range
』:
0~4300
『
Validate method
』:
Immediately
In the case of the tool life-span is specified, cutter output span reaches to the tool residual span
Summary of Contents for GSK988TA
Page 6: ...GSK988TA GSK988TA1 GSK988TB Turning Center CNC System User Manual Programming Operation VI ...
Page 19: ...1 Ⅰ Programming PROGRAMMING ...
Page 227: ...209 Ⅱ Operation OPERATION ...
Page 369: ...Chater 10 Machining Example 351 Ⅱ Operation ...
Page 371: ...353 Appendix ...
Page 465: ...Appendix 1 Parameters 447 Appendix ...
Page 479: ...Appendix 3 Interface Explanation 461 Appendix ...
Page 527: ...Appendix 5 Installation Layout 509 Appendix ...