GSK988TA/GSK988TA1/GSK988TB Turning Center CNC System User Manual
【
Programming & Operation
】
384
Appendix
『
Value Range
』
: 0
~
255
『
Default Setting
』
: 32
Set the dwell time when the resetting signal RST is output.
RST signal output time =resetting time + the parameter value X 16ms.
3019
Distribute the address of tool compensation value write-in signal
『
Modification authority
』
: Machine
『
Value Range
』:
0
~
127
『
Default Setting
』:
0
Set the address of tool compensation value write-in signal for distributing the X address.
3020
Distribute the bit address of the skip signal X address
『
Modification authority
』
: Machine
『
Value Range
』:
0
~
7
『
Default Setting
』:
0
Set the bit address for distributing the skip signal X address.
3021
Distribute the bit address of the multistep skips signal SKIP2
『
Modification authority
』
: Machine
『
Value Range
』:
0
~
7
『
Default Setting
』:
0
Set the bit address for distributing the multistep skips signal SKIP2
3022
Distribute the bit address of the multistep skips signal SKIP3
『
Modification authority
』
: Machine
『
Value Range
』:
0
~
7
『
Default Setting
』:
0
Set the bit address for distributing the multistep skips signal SKIP3
3023
Distribute the bit address of the multistep skips signal SKIP4
『
Modification authority
』
: Machine
『
Value Range
』:
0
~
7
『
Default Setting
』:
0
Set the bit address for distributing the multistep skips signal SKIP4
Summary of Contents for GSK988TA
Page 6: ...GSK988TA GSK988TA1 GSK988TB Turning Center CNC System User Manual Programming Operation VI ...
Page 19: ...1 Ⅰ Programming PROGRAMMING ...
Page 227: ...209 Ⅱ Operation OPERATION ...
Page 369: ...Chater 10 Machining Example 351 Ⅱ Operation ...
Page 371: ...353 Appendix ...
Page 465: ...Appendix 1 Parameters 447 Appendix ...
Page 479: ...Appendix 3 Interface Explanation 461 Appendix ...
Page 527: ...Appendix 5 Installation Layout 509 Appendix ...