Chapter 1 Overview
221
Ⅱ
O
p
eration
Button
Name
Function
Operation mode when
the function be valid
Single block
switch
Whether the single block running
is valid is controlled by the key,
When the button indicator lamp
is ON, the single block is valid.
Auto mode, MDI mode,
DNC mode
Block skip
switch
Whether the skip code “/” of the
program is valid is controlled by
the key, when the button
indicator lamp is ON, the skip
function is valid
Auto mode, MDI mode,
DNC mode
Machine
locked switch
When the machine is locked, the
machine locked indicator is ON
and each axis’ output is invalid
Auto mode, MDI mode,
Edit mode, Reference
point return mode, MPG
mode, Single step mode,
Manual mode, DNC mode
Miscellaneous
function locked
switch
The key is for switching the
status of the miscellaneous
function locked, M, S, T function
output is invalid when the
miscellaneous function is locked.
Auto mode, MDI mode,
DNC mode
Dry run switch
When the indicator lamp is ON,
dry run is valid. Machining
program is executed/MDI block
executes dry run.
Auto mode, MDI mode,
DNC mode
Optional stop
switch
When the optional stop is valid,
the indicator lamp is ON. When
M00 exists in the program, the
block stops after running
completes.
Auto mode, MDI mode,
DNC mode
Program
restart switch
The program restart is valid, the
program restart indicator is ON,
the program restarts at the place
where it stops previously.
Auto mode
Edit mode
key
Enter Edit mode key
Edit mode
Auto mode
key
Enter Auto mode key
Auto mode
MDI mode key Enter MDI mode
MDI mode
Summary of Contents for GSK988TA
Page 6: ...GSK988TA GSK988TA1 GSK988TB Turning Center CNC System User Manual Programming Operation VI ...
Page 19: ...1 Ⅰ Programming PROGRAMMING ...
Page 227: ...209 Ⅱ Operation OPERATION ...
Page 369: ...Chater 10 Machining Example 351 Ⅱ Operation ...
Page 371: ...353 Appendix ...
Page 465: ...Appendix 1 Parameters 447 Appendix ...
Page 479: ...Appendix 3 Interface Explanation 461 Appendix ...
Page 527: ...Appendix 5 Installation Layout 509 Appendix ...