BT, data block transfer
203
02/16 MN05013001Z EN
Example 3
: Initialisation of marker blocks, transfer of a
range to a different format.
The value of marker byte MB60 is to be transferred to MD80
and MD81.
• Parameters of function block BT01:
– Source range:
>I1 MB60
– Destination range: >I2 MD80
– Number of bytes:
>NO 8
h
The transfer is in byte format. MD80 has 4 bytes and
MD81 has 4 bytes, which means that >NO has the value
8.
Comparison
range 1
Value
marker
range 1
(dec./binary)
Comparison
range 2
Value of marker range 2 (decimal/binary)
MB60
45/
00101101
MD80
(Byte 1, LSB)
757935405/
001011010010110100101101
00101101
MD80
(Byte 2)
757935405/
0010110100101101
00101101
00101101
MD80
(Byte 3)
757935405/
00101101
00101101
0010110100101101
MD80
(Byte 4, MSB)
757935405/
00101101
001011010010110100101101
MD81
(Byte 1, LSB)
757935405/
001011010010110100101101
00101101
MD81
(Byte 2)
757935405/
0010110100101101
00101101
00101101
MD81
(Byte 3)
757935405/
00101100
01011011
0010110100101101
MD81
(Byte 4, MSB)
757935405/
00101101
001011010010110100101101