NC, numerical converter
287
02/16 MN05013001Z EN
BIN mode
The binary value present at input >I1 is converted to a BCD
value and supplied at the output QV>. The binary value is
displayed as a decimal value.
Example 1:
Input value >I1: +7
dec
BCD binary value: 0111
Hexadecimal value: 0111
Decimal value QV>: + 7
Example 2:
Input value >I1: +11
dec
BCD binary value: 00010001
Hexadecimal value: 00010001
Decimal value QV>: +17 (1 + 16)
Hexadecimal value:
Bit 0 has the value 1.
Bit 4 has the value 16
Total: Bit 0 plus bit 4 = 17
Example 3:
Input value >I1: 19
dec
BCD binary value: 00011001
Hexadecimal value: 00011001
Decimal value QV>: 25 (1 + 8 + 16)
Example 4:
Input value >I1: 9999999
dec
BCD binary value: 1001100110011001100110011001
Hexadecimal value: 1001100110011001100110011001
Decimal value QV>: + 161061273