TH, two-hand button
489
02/16 MN05013001Z EN
The circuit diagram in easySafety has three rungs:
Figure 252:
Example 1 two hand button: electrical circuit
diagram in easySafety
The input coils TH01I1 and TH01I2 of the function block are
associated directly with the device terminals IS10 and IS11,
the enable contact TH01QS switches the device output QS2
directly.
The enable parameter stays in the default setting, the evalu-
ation of the two hand button is switched to 1-channel (1CH).
The test signals for cross-circuit monitoring are assigned to
the corresponding device inputs in the TEST SIGNALSmenu.
IS10---------------------------
Ä
TH01I1
IS11---------------------------
Ä
TH01I2
TH01QS-------------------------
Ä
QS02
TH01 NEN *** *
*** 1CH
IS01 <- -
Æ
...
IS10 <- T3
IS11 <- T4
æ
...
IS14 <- -