Safety function blocks
480
02/16 MN05013001Z EN
The signal diagram of the function block for this application
shows:
• the dependencies of the enable contact of SG01QS on the
status of coils SG01I1, SG01I2 and SG01I3.
• the interrelationship between timed out discrepancy time
SG01DT and the error output SG01ER.
• the error acknowledgement with the coils SG01I1 and
SG01I2.
• the manual re-enabling after the safety gate is closed and
the Reset coil SG01RE has dropped out.
Figure 247:
Example 2 safety gate signal diagram
a
Closed safety gate, release of guard locking.
b
Opening of the safety gate, timeout of the discrepancy time.
c
Error acknowledgement by opening the safety gate.
d
Closing of the safety gate.
e
Guard locking.
f
Manual re-enabling after the Reset coil has picked up.
SG01I1
SG01I2
SG01QS
SG01ER
t > DT
SG01RE
SG01I3
a
b
c
d
e
f