FS, safety foot switch
387
02/16 MN05013001Z EN
Tabelle 14: Diagnostics-/-Error codes
Further information on these outputs is provided in section
“Common features”, page 348.
Coils and contacts
Function block coils initiate the functions of the function
block and monitor the connected safety transmitters.
The contacts of a safety function block confirm the enable
conditions present, selected operating modes or indicate
errors.
Coils
Connect the function block coils FS..I1 and FS..I4 directly to
the device terminals IS1 to IS14. The coils monitor the signal
of the foot switch in the safety circuit diagram.
Use function block coil FS..SA to activate the function block.
Associate the coil only in the safety circuit diagram for
example with the enable contact of another safety function
block.
Status number
Plain text
Hexadecimal (0–F)
decimal (0-9)
0000
0000
No Enable.
2001
8193
Enable issued; waiting for first (or only) input.
2011
8209
Foot switch not operated (position 0).
2013
8211
Foot switch in panic position (position 2).
2014
8212
Undefined foot switch position
8004
32772
Foot switch operated (position 1).
F002
61442
Error: Enable duration exceeded.
F00F
61455
Error: Foot switch 1/2 position is not permissible after
enable.
F010
61456
Error: Position 1 not permissible after panic position.
h
Activate the bridging of the guard with a key switch. The
key switch should be installed so that you have a complete
view of the hazardous zone.
Summary of Contents for easySafety
Page 1: ...Manual Control relay suitable for safety circuits Safety ES4P 02 16 MN05013001Z EN ...
Page 4: ...2 ...
Page 42: ...38 02 16 MN05013001Z EN ...
Page 80: ...Installation 76 02 16 MN05013001Z EN ...
Page 112: ...108 02 16 MN05013001Z EN ...
Page 606: ...602 02 16 MN05013001Z EN ...