TH, two-hand button
483
02/16 MN05013001Z EN
Parameters
When using the function block in the circuit diagram for the
first time, use OK to automatically enter the general display
of function block parameters, as shown in the figure on the
left. Enter the function block settings here. The display
contains the following elements:
The parameters consist of the following:
Enable
The enable coil TH..EN allows the selective activation or
deactivation of the function block. Further information can
be found at section “Enable parameter, EN enable coil” on
page 345.
Evaluation
This parameter defines how two hand buttons are to be
monitored:
• 1-channel with two make contacts or
• 2-channel with two make/break contact combinations
TH01 NEN *** *
*** 2CH
TH01
Function block: two hand button, No. 01
NEN
Enable: none required
2CH
Evaluation: 2-channel two hand button
Parameters
Function, parameterisation in the func-
tion block
EN
External enable required
NEN
(default settings)
Parameters
Function, parameterisation in the func-
tion block
1CH
1-channel evaluation
2CH
2-channel evaluation (default setting)