TS, Safety timing relay
497
02/16 MN05013001Z EN
Time base
This parameter set is used to define the switch times.
Time values
The parameters >T1 and >T2 are used to define one or two
time values depending on the switch function of the relay.
Parameters
Time base and set time
Resolution
S 000.000
[Seconds], 0.00 to 999.95 s for constants and
variable values
50 ms
M:S 00:00
[Minutes: Seconds] 00:00 to 99:59 only for
constants and variable values
1 s
H:M 00:00
[Hours: Minutes] 00:00 to 99:59 only for
constants and variable values
1 min.
h
Minimum time resolution: 0.05 s (50 ms)
If a time value is less than the easySafety cycle time, the
elapsed time will only be recognised in the next cycle.
The function block has a tolerance of
g
50 ms.
Parameters
Function
>T1
Time value 1
>T2
Time value 2